Abstract

ObjectivesThe aim of this study was to compare late-term clinical outcomes among patients treated with ultrathin-strut (60-μm) bioresorbable-polymer sirolimus-eluting stents (BP SES) and thin-strut (81μm) durable-polymer everolimus-eluting stents (DP EES). BackgroundEmerging evidence from comparative studies of drug-eluting stents demonstrates improved safety and efficacy with ultrathin-strut drug-eluting stents, but limited insight exists regarding late-term outcomes. MethodsBIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects With Up to Three De Novo or Restenotic Coronary Artery Lesions V) is an international randomized trial comparing coronary revascularization with BP SES and DP EES regarding the primary endpoint of 12-month target lesion failure. Analysis of pre-specified 3-year clinical outcomes was performed. ResultsAmong 1,334 patients randomized to treatment with BP SES (n = 884) or DP EES (n = 450), the 3-year rate of target lesion failure was 8.2% for BP SES and 13.6% for DP EES (p = 0.002), driven by differences in both target vessel myocardial infarction (MI) (5.0% vs. 9.2%; p = 0.003) and clinically driven target lesion revascularization (3.2% vs. 6.7%; p = 0.006). In landmark analysis, significant differences in target vessel MI and target lesion revascularization were observed favoring treatment with BP SES. Definite or probable late or very late stent thrombosis was significantly lower with BP SES (0.1% vs. 1.2%; p = 0.018). Cardiac death or MI rates were 7.7% and 11.7% (p = 0.017) for BP SES and DP EES, respectively. ConclusionsIn a large randomized trial, both target lesion failure and the outcomes of target vessel MI, clinically driven target lesion revascularization, and late or very late stent thrombosis at 3 years were significantly lower among patients treated with BP SES versus DP EES. The results endorse the continued superiority of ultrathin-strut BP SES compared with DP EES. (Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions [BIOFLOW-V]; NCT02389946)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.