Abstract

Hall elements were fabricated based on high quality chemical vapor deposition grown graphene, and their performance limit was explored. The as-fabricated graphene Hall element exhibits current-related sensitivity of up to 2093 V/AT under 200 μA, and magnetic resolution of around 1 mG/Hz0.5 at 3 kHz. This ultrahigh sensitivity and resolution stem from high carrier mobility, small Dirac point voltage of 3 V, and low carrier density of about 3 × 1011 cm−2 in graphene device. The current sensitivity is found to decrease with increasing current bias at large bias, and this phenomenon is attributed to the drain induced Dirac point shift effect in graphene channel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.