Abstract

The characteristics of the two-phase flow heat transfer of R-134a in microtubes with inner diameters of 430 μm and 792 μm were experimentally investigated. The effect of the heat flux on the heat transfer coefficient for microtubes was significant before the transition quality. The boiling number expressed the interrelation between the heat flux and the mass about the heat transfer coefficients. The smaller microtube had greater heat transfer coefficients; the average heat transfer coefficient for the tube A (Di = 430 μm) was 47.0% greater than that for the tube B (Di = 792 μm) at G = 370 kg/m2·s and q″ = 20 kW·m2. A new correlation for the evaporative heat transfer coefficients in microtubes was developed by considering the following factors: the laminar flow heat transfer coefficient of liquid-phase flow, the enhancement factor of the convective heat transfer, and the nucleate boiling correction factor. The correlation developed in present study predicted the experimental heat transfer coefficients within an absolute average deviation of 8.4%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.