Abstract

The paper presents novel algorithms for the off-state modelling of high-voltage devices with floating guard rings. The computation is based on quadratic isoparametric finite elements which improved accuracy in the determination of electric fields and ionisation integrals. The special boundary conditions for floating rings are considered together with an approach that automatically selects which ones to include in the calculations at a given bias. In addition, an efficient voltage-stepping technique is described for determining the breakdown voltage. Comparisons are made with measured values of floating ring potential and breakdown voltage on a variety of test devices with excellent agreement being found.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.