Abstract
Load frequency control (LFC) is an essential aspect of power system dynamics. This paper focuses on the optimization of LFC for a two-area deregulated power system under different scenarios. A recent nature-inspired ower pollination algorithm (FPA), based on the pollination process of plants, is used to tune the proportional integral (PI) controller parameters of LFC for the global minima solution. FPA is compared with a genetic algorithm, particle swarm optimization, and a conventional PI controller. During large load disturbance in the areas, controllers are incapable of reducing frequency deviations and tie-line power oscillations due to the slow response of the speed governor mechanism. Hence, to improve the dynamic response of the LFC, redox ow batteries (RFBs) are added to both areas due to their quick response and lower time constant. The simulation results show the effectiveness of the RFBs and FPA, especially in terms of overshoots, undershoots, and settling time, thereby improving the performance of LFC in the deregulated power system. The simulation was carried out on the MATLAB/Simulink platform.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.