Abstract

The effect of a combined system of the bed suction and jet injection as a pier-scour countermeasure on the turbulent flow field is studied in a laboratory flume using an Acoustic Doppler Velocimeter (ADV). The three components of the velocities in the vertical symmetry plane in the equilibrium scour hole in front and rear of the pier under 3-jet injections and bed suction rate Qs/Q0 = 2%located between 0 <x/D< 2.4, (where x and D are the horizontal distance along the streamwise direction between the suction source and the pier center and the pier diameter respectively); in clear-water scour condition were measured instantaneously. Also, characteristics of turbulence flow (the turbulence intensity, vorticity and turbulent kinetic energy) in the upstream of a circular pier were investigated. The results reveal that turbulence properties, such as turbulence intensities decrease with bed suction and jet injection. Over the entire water depth, they decrease more rapidly near the bed than those near the free surface. As a result, a system of jet injection and bed suction decrease scouring around the pier.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.