Abstract

The optical pyrometer is a widely used instrument for measuring the temperature of gas turbine blade targets. However, one of the limitations of this instrument is the measurement error caused by reflected radiation from the high-temperature surrounding environment. This paper presents an analysis of such measurement error with consideration of a wavelength detection range of 2.5 to 22μm with blade thermal barrier coatings (TBCs) ranging from 18 to 279μm. Surface temperature distributions were simulated using the software ANSYS CFX. Radiation heat transfer was calculated based on discretized triangular surface elements. The variation characteristics of relative temperature error under different wavelengths and TBC thicknesses were obtained. The results obtained are well suited to provide theoretical guidance for choosing the wavelength of a pyrometer when measuring blade temperature with different TBC thickness, and can also be used to provide a method for estimating and correcting the temperature error.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.