Abstract

The anodic depolarization wave of Hg +2 by complexone (ethylenediaminotetraacetic acid) has been found to be proportional to the concentration of complexone (10 -4 to 10 -3 mole/liter, pH =6.4 in buffered medium). Titrationc of complexone by Mn +2, Co +2, Ni +2, Cd +2, Mg +2, Zn +2 gave, at the same pH of 6.4, normal amperometric curves. On the other hand, alkaline-earth cations, the complexes of which are less stable than the aforementioned ones, gave abnormal amperometric curves in that the height of the wave observed during titration is much larger than the one corresponding to the concentration of the complexone that is not involved in the formation of the complex. These results can nevertheless be interpreted in a satisfactory way by assuming that the measured current is determined on the one hand by diffusion and on the other hand by the rate of dissociation of the complexes in the vicinity of the electrode. The rate constant is greater the less stable the complex.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.