Abstract

A PAssively Cooled, Electrically heated hydride (PACE) Bed has been deployed into tritium service in the Savannah River Site (SRS) Tritium Facilities. The bed design, absorption and desorption performance, and cold (non-radioactive) in-bed accountability (IBA) results have been reported previously. Six PACE Beds were fitted with instrumentation to perform the steady-state, flowing gas calorimetric inventory method. An IBA inventory calibration curve, flowing gas temperature rise (ΔT) versus simulated or actual tritium loading, was generated for each bed. Results for non-radioactive (“cold”) tests using the internal electric heaters and tritium calibration results are presented.Changes in vacuum jacket pressure significantly impact measured IBA ΔT values. Higher jacket pressures produce lower IBA ΔT values which underestimate bed tritium inventories. The exhaust pressure of the IBA gas flow through the bed’s U-tube has little influence on measured IBA ΔT values, but larger gas flows reduce the time to reach steady-state conditions and produce smaller tritium measurement uncertainties.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.