Abstract

Fowler–Nordheim plots of evaporated Si cold emitter arrays, tested in triode configuration at 42 and 300 K, are found to be temperature independent. Fluctuations in emission current decrease with decreasing temperature. Pressure dependence of collector current, measured in a diode configuration for collector voltage range of 90–130 V, shows a sharp decrease if the pressure is raised above 2×10−4 Torr.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.