Abstract

The present drying beds of Al-dubaiee waste water treatment station is not enough, thus, the present study is performed. In this work, many experiments have been made in order to find out the optimum thickness of the drying bed and to find suitable filtration agents from local materials. Moreover the effect of flocculent agents is tested. The results show that optimum thickness is 30 cm of brick and 25 cm of sand. Ferric concentration of 100 mg/l gives the best results. It is also found that drying efficiency is improved with reducing specific filtration resistance. The effluent waste water is found suitable for agriculture purpose concerned heavy metal concentration. special drying bed (handy slop towards center) is constructed and it is found that the required area is reduced by 50%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.