We have investigated the efficiency of ion trapping in a linear Paul trap. First, we measured the dependence of trapping efficiency on dc and rf voltages using a channel electron multiplier for the direct detection of the electric current of the trapped ions. The most efficient dc and rf voltages were 5.0 and 175 V, respectively. Second, we calculated the trapping efficiency using a simulation code and compared it with the experimental results. We determined that the efficiency of ion trapping decreased monotonically with increasing dc voltage and had an optimum rf voltage. From the numerical calculation, the dependences of trapping efficiency on dc and rf voltages and the initial kinetic energy of ions was derived and the optimum dc and rf voltages and the initial kinetic energy of ions were found to be 0, 210 V, and 1 eV, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.