Abstract

To prospectively evaluate the hypothesis that retrospectively electrocardiographically gated phase contrast with vastly undersampled isotropic projection reconstruction (VIPR) magnetic resonance (MR) angiography data sets can be used to measure transstenotic pressure gradients (TSPGs) in vivo. TSPGs were calculated by using phase-contrast VIPR MR angiography data sets; measurements obtained with a pair of endovascular pressure-sensing guidewires served as a reference standard. With institutional animal care and use committee approval, 12 swine underwent surgical creation of stenoses at the left common carotid, right renal, and left external iliac arteries. The percentage stenosis and reference diameter of the lesions were calculated from conventional digital subtraction angiograms. A pair of 0.014-inch pressure-sensing guidewires was placed in tandem; sensors 1 cm distal and 1 cm proximal to the lesions measured the mean TSPG. Phase-contrast VIPR phase difference images were analyzed with an iterative technique based on the Navier-Stokes equations to determine the mean TSPG. Pearson product correlation was calculated, and Bland-Altman plots were generated to determine the degree of agreement between the two methods. Twenty-one lesions (12 carotid, nine iliac; mean percentage stenosis, 52.4%; range, 29.8%-64.9%; mean reference diameter, 3.4 mm; range, 2.4-5.6 mm) were analyzed. For carotid and iliac lesions, phase-contrast VIPR and guidewire TSPG measurements were highly correlated (r = 0.952, P < .001). Bland-Altman plots (bias, 0.86 mm Hg; limits of agreement: -6.17 to 7.88 mm Hg) showed good agreement. Measurements in renal lesions (n = 9) were poorly correlated (r = -0.081, P = .835) and were excluded because of image degradation secondary to respiratory motion. Phase-contrast MR angiography with VIPR enables reliable measurements of TSPG in carotid and iliac lesions that are comparable to those obtained with endovascular pressure-sensing guidewires. However, further work to compensate for respiratory motion is required to extend this technique to the renal arteries.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.