Abstract

A theoretical investigation was conducted to study the transport-reaction process in the spray-drying flue gas desulfurization. A transport-reaction model of single particle was proposed, which considered the water evaporation from the surface of droplet and the reaction at the same time. Based on this model, the reaction rate and the absorbent utilization can be calculated. The most appropriate particle radius and the initial absorbent concentration can be deduced through comparing the wet lifetime with the residence time, the result shows in the case that the partial pressure of vapor in the bulk flue gas is 2000Pa, the optimum initial radius and absorbent concentration are 210–310 µ m and 23% respectively. The model can supply the optimum parameters for semi-dry FGD system designed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.