Abstract

The aim of this study was to analyze the Transit time flow measurement (TTFM) experience in the first 1000 CABG operations. First 1000 patients had coronary artery bypass grafting (CABG) performed in Cardiovascular Clinic, University Clinical Centre Tuzla, Bosnia and Herzegovina, between September, 1998 and September, 2003. CABG without use of cardiopulmonary bypass (CPB)-(OPCAB) was used as the preferential surgical method both because this method is reported to have equal or better results than CABG with use of CPB (ONCAB), and because of the significant cost savings realized. TTFM was routinely used in all grafts as a quality assurance measure. Criteria for a poor functioning graft were: low mean flow (MF), pulsatility index (PI) above 5 and a poor diastolic flow pattern. When no reversible cause of poor TTFM results were identified the graft was revised. A total of 1394 grafts in OPCAB group and 1478 in ONCAB group were performed. A total of 38 grafts (2,72%) in 37 patients (7,07%) were revised in OPCAB group, and 26 grafts (1,75%) in 26 patients (5,45%) in ONCAB group. 1 patient in OPCAB group needed 2 graft revisions. Graft revisions were more common in OPCAB, but with no significant difference (p=0,1035). The most frequently revised graft was LAD graft in both groups. Although the percentage of grafts revised are relatively low, it is still very important to record TTFM. More than 5% of patients in both groups needed graft revision. Although TTFM does not guarantee that grafts will stay open for a prolonged period of time we certainly believe that grafts that are occluded at the time of surgery will continue to stay occluded. TTFM is especially critical in OPCAB surgery where the technical challenge of grafting is higher then in ONCAB.

Highlights

  • Graft patency remains an important issue in coronary surgery ( )

  • The purpose of this study was to analyze the Transit time flow measurement (TTFM) experience in the first coronary artery bypass grafting (CABG) operations performed until September

  • Most revision were seen in the graft to LAD whether the operation was done as OPCAB or ONCAB

Read more

Summary

Introduction

Graft patency remains an important issue in coronary surgery ( ). Graft occlusion is a frequent cause of early death and perioperative myocardial infarction. Occluded grafts will limit the long term value of the operation. An accurate simple method of graft verification is important ( ). We have routinely used Transit time flow measurement (TTFM) (Cardiomed Flowmeter, Medistim AS, Oslo, Norway) in all patients after starting our cardiac surgery program. The purpose of this study was to analyze the TTFM experience in the first coronary artery bypass grafting (CABG) operations performed until September,

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.