Abstract

To determine the efficacy of the transfemoral vein approach to repositioning malpositioned central venous catheters. During a 4(1/2)-year period, malpositioned central venous catheters were repositioned 91 times in 83 patients via the transfemoral vein approach. All repositioning was initially attempted with a Grollman catheter or other pigtail catheter and a tip-deflecting wire. If these techniques failed or the venous anatomy was unfavorable, gooseneck or long loop snares were used. During 48 repositionings, rotating a pigtail-type catheter alone was used successfully in 39 (81%). In 6 of 9 failures, the addition of a tip-deflecting wire also failed. A Grollman catheter and tip-deflecting wire were used initially in 39 repositionings (6 failures; 85% success). Successful repositioning required a snare in 8 (4 as the primary repositioning technique) and a long-loop technique in 5. All repositionings were ultimately successful and there were no complications. Central venous catheters can be repositioned consistently by the transfemoral route. Pigtail catheters or tip-deflecting wires alone are successful in over 80% of cases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.