Abstract

Transesophageal echocardiography (TEE) was performed within 24 hours after cardiac catheterization in 45 patients for assessment of native mitral valvular regurgitation. Color flow mapping was used in evaluating systolic regurgitant jet sizes. A jet demonstrated by TEE was 96% sensitive and 44% specific for angiographic mitral regurgitation. The presence of angiographic mitral regurgitation was best predicted by (single measurement) (1) a holosystolic jet, (2) a jet length greater than 2.5 cm, and (3) a jet area greater than 2 cm2. Severe angiographic mitral regurgitation (grades 3 and 4) was best predicted by (single measurement) (1) a jet area greater than 5 cm2, and (2) a jet length greater than 4 cm. It is concluded that the assessment of angiographic mitral regurgitation by TEE is improved by the measurement of these jet parameters, which have a high sensitivity and higher specificity than the presence of a jet alone. Furthermore, with TEE one is able to differentiate severe (grades 3 and 4) from absent or mild mitral regurgitation (grades 0, 1, and 2).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.