Abstract
Bridging of vitamin K antagonist (VKA) with heparin is usually not promoted during interventional or surgical procedures related to increased risk of bleeding and thrombotic events but this strategy has not been evaluated during transcatheter aortic valve implantation (TAVI). The aim of this study was to evaluate the rate of major bleeding and vascular complications after TAVI performed in patients with uninterrupted VKA. From January 2016 to October 2017, consecutive patients who underwent TAVI with uninterrupted VKA (International Normalized Ratio [INR]between 1.5 and 3.5) were prospectively included in a monocentric registry. TAVI was performed according to current guidelines and a 50 U/kgbolus of heparin was injected at the beginning of the procedure for all patients. Vascular and bleeding complications were assessed using the Valve Academic Research Consortium 3 (VARC3) and the Bleeding Academic Research Consortium (BARC) definitions at a 30-day follow-up. A total of 88 patients were included with a median age of 84 years (81.8-87.0), 42% being female. The median society of thoracic surgeons score was 5.1 (4.1-7.5), the median CHADS2-VAScwas 5.5 (5-6)and 60.2% had a chronic kidney failure. Median INR at the time of implantation was 2.1 (1.8-2.6). The main VKA indication was atrial fibrillation. Transfemoral access was used in 88.6% of the patients. Major bleeding (BARC ≥ 3b) occurred in five patients (5.7%) and major vascular complications occurred in seven patients (8.0%). At 1month follow-up, major bleeding (BARC ≥ 3) or vascular complications occurred in 10 patients (11.4%). In patients with major bleeding peripheral arterial disease (RR = 10.95; 95% confidence interval (CI) 1.63-73.75; p = 0.014) and carotid access (RR = 8.56; 95% CI 1.19-1.51; p = 0.033) were more common. INR > 2.5 was significantly associated with vascular complications (RR = 7.14; 95% CI 1.29-39.63; p = 0.025). At 30 days, mortality and stroke rates were 2.3% and 4.5%, respectively. TAVI with uninterrupted VKA treatment seems feasible and safe with a low risk of major bleeding and vascular complications in this first single-center experience. Particular caution is advocated in high body mass index patients and to keep INR < 2.5.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.