Abstract

Background: Data on neonatal tracheal length are needed to inform the standardization of safety features for endotracheal tubes (ETTs) such as glottic depth markings. Laryngotracheal airway measurements are available from digital imaging in infants and children but not in neonates. We aimed to determine the tracheal length (TL) of intubated preterm and term neonates. Methods: An observational study was performed on 57 neonates of 22–42 weeks’ gestation and <1 week of age. Two clinicians independently reviewed 153 digital chest radiographs to determine the carina position and TL. TL was measured from carina to mid-C4 (cricoid level). We analyzed interrater agreement (within 0.5 vertebral levels) on the position of the carina and TL. TL was plotted as a function of gestational age and weight, using graphical and regression analyses. Results: Carina position ranged from T3 to T5.5, with an interrater agreement of 95%. On image pairs concordant for carina position, TL determinations were virtually identical between readers (mean difference 0.1 mm, 95% CI −0.5–0.6 mm). Average mid-tracheal length overlies the body of T1. In infants aged less than 32 weeks’ gestation, the mid-trachea lies <20 mm from the carina or the larynx. TL linearly correlates with gestational age, but correlation with birthweight best fits a segmented regression with a node at 1 kg. Conclusions: The functional length of the laryngotracheal airway can be reliably measured in sick neonates. It correlates well with gestational age and birthweight, and this information can inform the redesign of ETT markings to promote the safer use of these devices.

Highlights

  • The functional length of the laryngotracheal airway can be reliably measured in sick neonates

  • The two authors independently reviewed 153 digital chest radiographs from neonates

  • Six radiographs excluded from analysis because the carina could not be visualized; or, ribs and vertebral were excluded from analysis because the carina could not be visualized; or, ribs and verbodies could not be counted consistently due to exposure or overlying equipment, leaving tebral bodies could not be counted consistently due to exposure or overlying equipment, 108 radiographs for the present tracheal length analysis

Read more

Summary

Introduction

The short length of the neonatal trachea allows for very narrow tolerances in the safe position of endotracheal tubes [1]. Data on neonatal tracheal length are needed to inform the standardization of safety features for endotracheal tubes (ETTs) such as glottic depth markings. Laryngotracheal airway measurements are available from digital imaging in infants and children but not in neonates. We aimed to determine the tracheal length (TL) of intubated preterm and term neonates. We analyzed interrater agreement (within 0.5 vertebral levels) on the position of the carina and TL. Results: Carina position ranged from T3 to T5.5, with an interrater agreement of 95%. On image pairs concordant for carina position, TL determinations were virtually identical between readers (mean difference 0.1 mm, 95% CI −0.5–0.6 mm).

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.