Abstract
BackgroundThe reconstructive challenge of achieving a stable acetabulum in revision total hip arthroplasties in the presence of major osteolytic lesions has led to debate about the most appropriate surgical strategy to minimize implant-related failures. Trabecular metal (TM) implants have become popular but ongoing surveillance of their performance is required. MethodsWe reviewed the clinical and radiological outcome of a consecutive series of 52 patients (55 hips) who had undergone revision total hip arthroplasty for Paprosky type 2 or 3 acetabular defects with TM revision acetabular shells between 2002 and 2008. ResultsFour implant failures occurred (2 infections and 2 dislocations). Eleven patients from this cohort died (representing 12 hips) before the 5-year follow-up period giving us a follow-up of 78.2%. Implant survival at 5 years was 92% (95% confidence interval: 80.2%-96.9%). There were no cases of radiological loosening. The mean Oxford hip score was 34 (range, 5-48) at a mean follow-up of 63 months (range, 34-105 months). ConclusionsWe conclude that the use of TM revision shells for complex acetabular reconstruction yields satisfactory results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.