Abstract

ObjectivesFetal heart rate variability (FHRV) has shown potential in fetal surveillance. Therefore, we aimed to evaluate the reliability of time domain and spectral domain parameters based on non-invasive fetal electrocardiography (NI-FECG).MethodNI-FECG, with a sampling frequency of 1 kHz, was obtained in 75 healthy, singleton pregnant women between gestational age (GA) 20+0 to 41+0. The recording was divided into a) heart rate pattern (HRP) and b) periods fulfilling certain criteria of stationarity of RR-intervals, termed stationary heart rate pattern (SHRP). Within each recording, the first and the last time series from each HRP with less than 5% artifact correction were analyzed and compared. Standard deviation of normal-to-normal RR-intervals (SDNN), root mean square of successive differences (RMSSD), high frequency power (HF-power), low frequency power (LF-power), and LF-power/HF-power were performed. A multivariate mixed model was used and acceptable reliability was defined as intraclass correlation coefficient (ICC) ≥ 0.80 and a coefficient of variation (CV) ≤ 15%. Based on these results, the CV and ICC were computed if the average of two to six time series was used.ResultsFor GA 28+0 to 34+6, SDNN and RMSSD exhibited acceptable reliability (CV < 15%; ICC > 90%), whereas GA 35+0 to 41+0and 20+0 to 27+6 showed higher CVs. Spectral domain parameters also showed high CVs However, by using the mean value of two to six time series, acceptable reliability in SDNN, RMSSD and HF-power from GA 28+0 was achieved. Stationarity of RR-intervals showed high influence on reliability and SHRP was superior to HRP, whereas the length of the time series showed minor influence.ConclusionAcceptable reliability seems achievable in SDNN, RMSSD and HF-power from gestational week 28. However, stationarity of RR-intervals should be considered when selecting time series for analyses.

Highlights

  • Heart rate variability (HRV), in the form of time domain and spectral domain analyses, reflects the autonomic nervous system in adults [1], neonates [2, 3] and fetuses [4, 5]

  • Acceptable reliability seems achievable in Standard deviation of normal to normal RR-intervals (SDNN), Root mean square of successive RR-interval differences (RMSSD) and High frequency (HF)-power from gestational week 28

  • Reliability in fetal heart rate variability by time domain and spectral domain analyses For each gestational age and under the assumptions in the mixed model, we computed the PI, Coefficient of Variation (CV) and Intraclass Correlation Coefficient (ICC) within each fetus if the average of two to six time series are used as measurement

Read more

Summary

Results

For GA 28+0 to 34+6, SDNN and RMSSD exhibited acceptable reliability (CV < 15%; ICC > 90%), whereas GA 35+0 to 41+0and 20+0 to 27+6 showed higher CVs. Stationarity of RR-intervals showed high influence on reliability and SHRP was superior to HRP, whereas the length of the time series showed minor influence.

Introduction
Methods
Discussion
Findings
Strengths and limitations
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.