Abstract
A patient previously treated by cannulated screws fixation of a femoral neck fracture and plate and screw fixation of an ipsilateral shaft fracture presented for a total hip arthroplasty due to femoral head avascular necrosis. The cortical bone at the previous fracture site was weak and damage on the proximal femur was considered likely during removal of the plate. We were also concerned that a periprosthetic fracture might occur during or after the insertion of a conventional femoral stem. We used a short-stemmed femoral component for total hip arthroplasty in this patient, to avoid the risk of potential complications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.