A total energy balance method for venting electric tumbler dryers was developed and the experimental methodology and calculation details are provided in this article. The energy to evaporate the water in the load; the energy to heat the water, textile, and dryer; energy losses by convection and radiation; and the energy not used in the process were considered to calculate the total output energy. This method was applied to a domestic venting electric tumble dryer. The results of the method suggested areas of improvement. The maximum difference between the measured total input and the calculated total output energies was 2.6%, indicating the accuracy of the method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.