Abstract

The presented time-domain EMI measurement system allows for full-compliance measurements according to CISPR 16-1-1 in the frequency range from 9 kHz to 26 GHz. With the combination of ultra-fast analog-to-digital-conversion and real-time digital signal processing on a field-programmable-gate-array (FPGA) with ultra-broadband multi-stage down-conversion, time-domain methods are employed for measurements into K-band. This allows for a reduction in scan times by several orders of magnitude. A scan from 9 kHz to 26 GHz with a 9 kHz IF-filter bandwidth is completed in under 200 s, while over 5 · 10 6 frequency points are calculated. The use of low-loss components and integrated preamplifiers yields an ultra-low system noise floor power spectral density of typically below –150 dBm/Hz. The system IF dynamic range of over 60 dB allows for the measurement of high-dynamic range signals like radar pulses. Measurements of the radiated emissions of a personal computer and the nonstationary emissions of a microwave oven are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.