Abstract
Abstract. In this study a photoacoustic spectrometer (PA), a laser-induced incandescence instrument system (LII) and an Aerosol Mass Spectrometer were operated in parallel for in-situ measurements of black carbon (BC) light absorption enhancement. Results of a thermodenuder experiment using ambient particles in Toronto are presented first to show that LII measurements of BC are not influenced by the presence of non-refractory material thus providing true atmospheric BC mass concentrations. In contrast, the PA response is enhanced when the non-refractory material is internally mixed with the BC particles. Through concurrent measurements using the LII and PA the specific absorption cross-section (SAC) can be quantified with high time resolution (1 min). Comparisons of ambient PA and LII measurements from four different locations (suburban Toronto; a street canyon with diesel bus traffic in Ottawa; adjacent to a commuter highway in Ottawa and; regional background air in and around Windsor, Ontario), show that different impacts from emission sources and/or atmospheric processes result in different particle light absorption enhancements and hence variations in the SAC. The diversity of measurements obtained, including those with the thermodenuder, demonstrated that it is possible to identify measurements where the presence of externally-mixed non-refractory particles obscures direct observation of the effect of coating material on the SAC, thus allowing this effect to be measured with more confidence. Depending upon the time and location of measurement (urban, rural, close to and within a lake breeze frontal zone), 30 min average SAC varies between 9 ± 2 and 43 ± 4 m2 g−1. Causes of this variation, which were determined through the use of meteorological and gaseous measurements (CO, SO2, O3), include the particle emission source, airmass source region, the degree of atmospheric processing. Observations from this study also show that the active surface area of the BC aggregate, which is measured by the LII as the PPS, is an important parameter for inferring the degree of particle collapse of a BC particle. In addition, PPS could be a useful measurement for indicating the importance of recently emitted BC (e.g. from gasoline or diesel engines) relative to the total measured BC in the atmosphere.
Highlights
Black carbon (BC) particles are released into the atmosphere from incomplete combustion of fossil and biofuels, and biomass burning (Horvath, 1993)
Observations from this study show that the active surface area of the black carbon (BC) aggregate, which is measured by the laserinduced incandescence (LII) as the primary particle size (PPS), is an important parameter for inferring the degree of particle collapse of a BC particle
A thermodenuder was used at an urban site to study the effect of volatile and semi-volatile particle coating mass on fine BC particles using photoacoustic spectrometer (PA) and laserinduced incandescence (LII) instruments
Summary
Black carbon (BC) particles are released into the atmosphere from incomplete combustion of fossil and biofuels, and biomass burning (Horvath, 1993). In the second component of our experiment, the instruments were deployed to contrasting locations to measure the ambient BC particles using the LII and PA, but without thermodenuder alterations These measurements were undertaken to determine if it is possible to observe in-situ urban to regional scale variations in the coating effect on BC light absorption properties within different air masses. During BAQS-Met the mobile lab was deployed to an industrially-impacted urban site in west Windsor, Ontario, and to rural locations in southwestern Ontario Through these strategic deployments our objective was to quantify the range of variability in the coating enhancement in BC light absorption, to understand how quickly the enhancement can change due to changes in coating relative to BC mass, and possible causes of these changes related to BC www.atmos-chem-phys.net/11/10407/2011/. The SAC results in this study were quantified with 1 min time resolution from a combination of measurements using the LII and PA instruments
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.