Abstract
We have measured the time resolutions which can be obtained in hadronic showers from a scintillation counter hodoscope and a scintillating fibre counter at various shower depths. The hodoscope was made of 100×2×1 cm 3 BICRON 404 scintillators. The fiber counter consisted of four layers of fibers (SCSN-38, 1 mm diameter) embedded in lead with the dimensions 100×20×1 cm 3. The performance of these counters was compared for two different types of photomultipliers: Hamamatsu R2083 and Philips XP2020.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.