Abstract

BackgroundPeriprosthetic fracture of the tibia after unicompartmental knee arthroplasty has been reported to be associated with excessive pin holes created for stabilization of the cutting guide. However, fractures have also been reported in cases using two pins as in the method suggested by the manufacturer. It is currently unclear whether variations in pinhole positions make a difference in proximal tibial fracture risk.MethodsFinite element models were constructed using Chinese female bone computed tomography images, with bone cuts made according to the surgical steps of implanting a fixed bearing unicompartmental arthroplasty. Four combinations of pinholes (pins placed more closely to the medial tibial cortex or centrally along the mechanical axis as allowed by the tibial cutting guide) created for tibial cutting guide placement were tested by finite element analyses. Testing loads were applied for simulating standing postures. The maximum von Mises stress on the tibial plateau was evaluated.ResultsPinhole placed close to the medial edge of the proximal tibial plateau is associated with the highest stress (27.67 Mpa) and is more likely to result in medial tibial fracture. On the contrary, pinhole placed along the central axis near the tibial tuberosity has the lowest stress (1.71 Mpa) and reflects lower risk of fracture.ConclusionThe present study revealed that placing tibial cutting guide holding pins centrally would lower the risks of periprosthetic fracture of the medial tibial plateau by analyzing the associated stress in various pin hole positions using finite element analysis.

Highlights

  • Unicompartmental knee arthroplasty (UKA) in appropriately selected patients is one of the successful treatment options for unicompartmental osteoarthritis with 10-year survivorship that ranges from 91.4 to 98% [1, 2]

  • Periprosthetic fracture after UKA, rare, is one of the possible complications and may necessitate complex revision and restriction in patient activities [4]. It commonly presents as medial tibial plateau stress fracture underneath the UKA tibial baseplate

  • Periprosthetic fracture over the medial tibial plateau underneath the tibial baseplate is a devastating complication after UKA

Read more

Summary

Introduction

Unicompartmental knee arthroplasty (UKA) in appropriately selected patients is one of the successful treatment options for unicompartmental osteoarthritis with 10-year survivorship that ranges from 91.4 to 98% [1, 2]. Periprosthetic fracture after UKA, rare, is one of the possible complications and may necessitate complex revision and restriction in patient activities [4]. It commonly presents as medial tibial plateau stress fracture underneath the UKA tibial baseplate. Fractures have been reported in cases using two pins as in the method suggested by the manufacturer. It is currently unclear whether variations in pinhole positions make a difference in proximal tibial fracture risk

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.