Abstract

Purpose360-degree gonioscopy-assisted transluminal trabeculotomy (GATT) is a safe and effective angle-based intervention to lower IOP. Use of the iTrack Advance allows the surgeon to efficiently advance the microcatheter in one continuous motion with a slider, an improvement upon previous techniques in which microcatheters or sutures which had to be manually threaded through Schlemm’s canal with microforceps. This report demonstrates three variations in surgical technique for successful 360-degree GATT using the iTrack Advance. ObservationsThe first technique requires retrieval of the tip of the microcatheter and requires an assistant to hold the gonioprism. The second method also requires retrieval of the tip of the microcatheter, but does not require an assistant to hold the gonioprism. The third technique does not require retrieval of the tip of the microcatheter or an assistant for the gonioprism. Conclusionsand Importance: The three techniques presented here allow for the completion of a 360-degree GATT using the iTrack Advance without having to manually thread a microcatheter or suture through Schlemm’s canal.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.