Abstract

A hydrogen sensor working at room temperature with high sensitivity, good selectivity and simple structure was presented in this paper. Four couples of P- and N-type bismuth–telluride films were connected in series to serve as the feedback part of the hydrogen sensor with a high Seebeck coefficient of 1.1 mV/K. A platinum catalyst was deposited on γ-Al2O3 acting as a sensitive part. Linear relationships between the output voltage and the hydrogen concentration as well as the flow rate were found when the hydrogen concentration was higher than 0.5 vol.%. As for the 3 vol.% H2/Air gas with a 100 ml/min flow rate at room temperature, the response and recovery times were about 30 and 55 s, respectively, and the error of repeatability was less than 0.3%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.