Abstract

This study presents an analysis of an existing biogas engines-powered cogeneration system installed in Varna Wastewater Treatment Plant, Bulgaria using thermoeconomic method. The thermoeconomic analysis is conducted using three different groups of environmental conditions. The SPECO (specific exergy cost) method is applied to the system and cost balance equations are formulated for each component. The fuel F and the product P rules are used to obtain auxiliary equations. Moreover, in this paper, various thermoeconomic performance parameters such as the cost of exergy destruction, the relative cost difference and the exergoeconomic factor are determined. The obtained results show that the specific unit exergetic cost of the electrical power produced by the cogeneration system are found to be 30.0€/GJ = 0.11€/kWh, while the conducted thermoeconomic analysis based on energy delivers a result of 0.19€/kWh for the electrical work produced by biogas engines. In addition, the obtained results are compared to those seen in similar studies.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.