Abstract

The speed of sound in the R-415A refrigerant vapor and its density and pressure on the condensation line were measured by the ultrasonic interferometer and constant-volume piezometer methods within a range of temperatures from 293 to 373 K and pressures from 0.04 to 0.5–2.45 MPa. The temperature, pressure, density and speed of sound measurement errors were ±20 mK, ±4 kPa, and ±(0.1–0.2)%, respectively. The temperature dependence of the ideal-gas heat capacity was calculated on the basis of the obtained data. The obtained results were compared with the properties calculated by the REFPROP software.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.