Abstract

A control system using a low-drift power-feedback signal was implemented applying thermal waves, giving a sensor output independent of resistance drift and thermo-electric offset voltages on interface wires. Kelvin-contact sensing and power control is used on heater resistors, thereby inhibiting the influence of heater resistance drift. The thermal waves are detected with a sensing resistor using a lock-in amplifier and are mutually cancel­led by a thermal-wave balancing controller. Offset due to thermal gradient across the chip and resistor drift are eliminated by the lock-in amplifier and power controller, and therefore do not influence the sensor output signal. A microchannel thermal-wave balancing flow sensor with integrated Al resistors has successfully been fabricated. The thermal flow sensor is capable of measuring water flow rates with nl ⋅ min−1 precision, up to about 500 nl ⋅ min−1 full scale. Measurement results are in good agreement with a dynamic model of the flow sensor. Drift measurements show the sensor output signal to be compensated for resistance drift and thermal gradient across the chip.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.