Abstract

A 1-D transient model (RESHEAT), developed by the writers, was used to study the thermal performance of a highly reflective paint applied sequentially to the outer walls and roof of a simulated residence in a hot and arid region of the southwestern United States. The model uses climatological inputs from a file that includes hourly data on ambient temperatures, insolation, cloud cover, and so on, at the particular location. The model focuses particularly on the potential cooling load reduction due to the reduced heat pickup from the inside attic surfaces to the outer surfaces of the supply duct. This simulation showed that a reduction of 33.6% (cooling load) on the average is achieved over the base case where no reflective paint is used when the outer surface of the roof and walls are painted. Alternatively, only a 11% reduction would be achieved if the reflective paint is applied only to the roof. Savings of $42 per month are conservatively estimated from calculations made when applying this technology to a typical residence (roof and walls) equipped with a 4 ton refrigeration unit in the Southwest.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.