Abstract

A proper thermal management strategy is needed to maintain uniform temperature distribution and derive optimal performance in high temperature proton exchange membrane fuel cells (HT-PEMFC). In HT-PEMFCs, more than half of the chemical energy is converted into thermal energy during the electrochemical generation of electrical power. We investigate the viability of three heat removal strategies: (a) using cooling plates through which cathode air is passed in excess of stoichiometric requirement for the purpose of heat removal, (b) using forced convection partly in conjunction with cooling plates, and (c) using forced convection alone for heat removal. Calculations, partly done using computational fluid dynamics simulations, for a 1 kWe HT-PEMFC stack, which is suitable for scooter type of transport applications, show that a combination of excess stoichiometric factor and forced draft appears to provide the optimal strategy for thermal management of high temperature PEM fuel cells. With proper cooling strategy, the temperature variations within the cell may be reduced to about 20 K over most of the cell and to about 50 K in isolated spots.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.