Abstract
For the development of a 30-MJ, 7-T/s pulsed coil, a 30-kA cable-in-conduit conductor with low pulsed loss was designed and fabricated. The Japan Atomic Energy Research Institute performed verification tests to measure the temperature increase when a high-energy disturbance of 300 mJ/cc-strand is put into the superconducting strands and also to measure the stability margin of the conductor, which is increased by a factor of 1.65 when the He flow rate is increased from 0 to 1.0 g/s at the nominal current under 7 T. A possible mechanism to explain this improvement is discussed.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.