This study explores the design of a novel passive mixer based on the concept of a coiled flow inverter (CFI) with an enhanced heat transfer efficiency. The proposed wavering coiled flow inverter (WCFI) was designed by inserting a 90° bend in halfway of the helical coils of equal arm lengths and wavering curvature radius. The hydrodynamics and thermal performance of the developed WCFI were than compared with helical coiled tube (HCT) and CFI with the same heat transfer areas (At = 0.062 m2 and 0.157 m2). Water was used as the working fluid in a range of Dean number from 8 to 1581. The designed WCFI, showed a 48% enhancement of the Nusselt number over an HCT with the same heat transfer area. Furthermore, the WCFI provided an 18% higher Nusselt number than the CFI due to the wavering curvature effects. Additionally, the friction factor data were practically comparable to that of the HCT. This study offers a preliminary investigation of the local and average heat transfer advantages of using a novel passive device WCFI. The present work may be significant, as it offers heat transfer augmentation via intensified geometrical design, without additional pressure drop.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.