Abstract

Despite the high theoretical performance limits of magnetic refrigeration systems, coefficient of performance (COP) of these systems can be lower due to abortive magnet and magnetocaloric material (MCM) assembly orientation and space limitation. To address both of these problems, a rotary-type magnetic cooling system with varied geometric properties was modelled and simulated. Heat transfer from the MCM, which was selected to be gadolinium (Gd), to the working fluid, was considered as volumetric energy generation. Three different geometries of disc-MCM assembly were studied where the inner and outer radii were selected as 5, 10, 15 mm, and 10, 15, 20 mm, respectively. It was observed that the gradient between steady-state temperature and the room temperature decreases with decreasing gadolinium-to-disc area ratio. Conductive heat transfer through the thickness of the disc was found to be inconsiderable compared with the convective heat transfer through the top surface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.