Abstract

The effect of the laminate stacking factor on homopolar magnetic bearing performance is examined. Stacked laminates are used on the bearing rotor and in the stator. These laminate stacks have anisotropic permeability. Equations for the effect of the stacking factor on homopolar bearing position stiffness are derived. Numerical results are calculated and compared to measurements. These results provide an answer for the common discrepancy between test and theory for homopolar magnetic bearing position stiffnesses.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.