Abstract

The retention and peak spreading in linear gradient elution of charged large biomolecules were investigated by using numerical simulations. Oligo-DNA separation by monolithic anion-exchange chromatography was chosen as a model system. The peak width and the retention were well predicted by using the parameters obtained by gradient elution experiments at different gradient slopes. As the distribution coefficient at the peak retention volume K R decreases with increasing molecular size, the peak became sharper for larger DNAs. This is due to very large effective charge (binding site) values of large DNAs (20–60). The peak width was well correlated with K R based on the model equation developed for linear gradient elution of proteins. It was shown that the monolithic disk is best suited for very large charged biomolecule separations at high flow velocities with shallow gradients slopes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.