Abstract

The index n of the voltage-current characteristic of large superconductors is a crucial parameter to assess the allowed range for coil operation. In the tests of the Insert coils at the CSMC as well as in the short sample test in the SULTAN facility, it is observed that the index n dramatically decreases from the Nb/sub 3/Sn strands extracted from cable-in-conduit provide the evidence of a permanent performance drop in the strands, likely due to the transverse load accumulation at the strand crossovers in the cable. This effect is not observed in NbTi conductors. The immediate implications for the Nb/sub 3/Sn conductor design are discussed and layout modifications to mitigate the effect are proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.