Abstract

This paper describes a simple method for incorporating the effects of the uniform risk spectra (URS) in the seismic probabilistic safety assessment (PSA) for a pressurized water reactor (PWR) power station. The “traditional” fragility parameters for a range of critical equipment items in a PWR power station on two typical UK sites are modified to incorporate the URS using this simple method and the effect on the high confidence low probability of failure (HCLPF) acceleration levels and seismic-induced failure probabilities of the equipment items is examined. The results illustrate the potential benefit of using the URS in the seismic PSA for a PWR power station.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.