Abstract

The use of dynamic ultrasound B-scan to detect retinal tears in spontaneous vitreous haemorrhage is described. A 6-month prospective study was undertaken of non-diabetic patients who presented with spontaneous vitreous haemorrhage, in whom the fundus could not be visualised and in whom a rhegmatogenous aetiology was suspected. Patients were followed up at least weekly with repeat B-scans until adequate fundus visualisation was possible. Eight patients in total were included in the study; of these, 4 were thought to have retinal tear at initial ultrasound examination and this was confirmed later when the haemorrhage cleared. A scanning protocol is suggested.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.