Abstract
The time course of the impedance changes caused by the contralateral acoustic reflex was investigated in five normal hearing, young adult subjects The acoustic reflex function was measured with equipment having a time constant of 15 milliseconds which permitted precise temporal measures. Temporal intervals from signal onset and termination to various portions of the acoustic reflex function were derived using an analysis procedure based on the slope function underlying the acoustic reflex response. These temporal intervals are related to physiological events underlying the acoustic reflex.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.