Abstract

The spontaneous ignition potential of a super-light crude oil was investigated employing adiabatic, packed-bed reactors. Various process parameters such as initial reactor temperature, oxidant gas flux, oxygen concentration in the oxidant gas, initial oil and water saturations and reactor pressure were varied to determine the set of conditions that would cause the sand–oil mixture to ignite spontaneously. All attempts to ignite the oil failed even when very favorable ignition conditions were tested including 174°C initial temperature, 7340 kPa reactor pressure, 40% oxygen in the oxidant gas and 26 h of oxidation time. Failure of the super-light crude to self-ignite was thought to be due to its low content of unsaturates, mainly aromatics and asphaltenes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.