Abstract

Purpose – The purpose of this paper is to improve the accuracy and signal-to-noise ratio (SN) of a crop nitrogen sensor. Design/methodology/approach – The accuracy and wide adaptability of two spectral calibration methods for a crop nitrogen sensor based on standard reflectivity gray plates and standard detector, respectively, were compared. Findings – The calibration method based on standard detector could significantly improve the measurement accuracy and the SN of this crop nitrogen sensor. When compared with the method based on standard gray plates, the measurement accuracy and the SN of the crop nitrogen sensor calibrated based on the standard detector method improved by 50 and 10 per cent, respectively. Originality/value – This research analysed the calibration problems faced by the crop nitrogen sensor (type CGMD302) based on standard gray plates, and proposed a sensor calibration method based on a standard detector. Finally, the results of the two calibration methods were compared in terms of measurement accuracy and the SN of the crop nitrogen sensor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.