Abstract

In order to detect the small neutrino fluxes expected at ultra-high energies, large volumes of materials have to be instrumented with inexpensive but sensitive acoustic sensors. The South Pole Acoustic Test Setup (SPATS) will be installed in the Antarctic ice during the polar season 2006/2007 after which the collected data will be used to reveal the acoustic properties of the South Polar ice cap. The developed piezoceramic based ultrasound sensors and transmitters that are part of this system have been extensively studied during calibration measurements in water, using a commercial hydrophone as reference. Also, a SPATS system test was accomplished in Lake Torneträsk, Abisko (Sweden). This allowed verification of the DAQ system, transmitter range and sensor performance. Here the results of the calibrations and the Abisko lake measurements are reported.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.