Abstract

Large time-bandwidth product coded signal and pulse compression are introduced into ultrasonic testing. Linear frequency modulation (LFM) excitation is usually used to improve time resolution, but sidelobe should be suppressed to detect smaller flaws nearby. Barker coded excitation is usually used to suppress sidelobe, but time resolution of results is lower than LFM excitation. So frequency-phase coded excitation is proposed to obtain higher time resolution and lower sidelobe level. The proposed excitation signal is applying LFM to each sub-pulse of Barker code, and it is called LFM-B13. The results of simulations demonstrate that, time resolution of LFM-B13 excitation is approximately 40% higher than that of LFM excitation, and main sidelobe level of LFM-B13 excitation is approximately 4 dB lower than that of LFM excitation, when 60% bandwidth of 5 MHz central frequency transducers are used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.