Abstract

The sensitivity to the axial neutron flux distribution of the positive reactivity that may have been introduced on initiation of scram in Chernobyl-4 has been evaluated. It is found that the scram reactivity is positive and its size is remarkably insensitive to a wide range of axial flux distortion provided the flux shape is concave, which is a characteristic of neutronic decoupling of the core. In contrast, the scram reactivity is negative when flux shapes are convex, i.e., those that are a characteristic of strong neutronic coupling. This indicates that unless there were a significant number of control absorbers present in the core just before the accident to provide a convex flux shape, the chances that some positive scram reactivity was inserted to initiate the power pulse are high.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.