Abstract

Rain has long been a problem for land seismic surveys. I measured the seismic signature of rainfall using both water dripped from height using a pipette, and natural rain in Winchester, England, over a three month period. My results showed that rain noise is concentrated at frequencies above 80 Hz with a detectable range of less than 1 m. Drops of water landing directly on a geophone result in events with amplitudes nearly 30 times larger than those landing next to the geophone. Items placed on the surface of the ground, such as cables, absorb the energy of the impact and reduce the level of the resulting seismic noise. Burying geophones results in attenuation of rain noise by between 7.7 and 8.6 dB/0.1 m. But, given the effort required to bury geophones, it is likely that data processing algorithms, or the placement of vibration absorbent matting, are likely to be the preferred strategies for dealing with noise.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.