Abstract

We have performed AC susceptibility measurement and shown the property of the vortex glass in the region near the pinned vortex liquid, where it is proposed that the velocity of flux diffusion, ν=ν0(j/jc)exp(-U/T), instead of ν=ν0exp(-U/T) in the region far away from the glass melting line for providing a gradual crossover to the viscous flux flow regime (ν ∝j, where j is current density). It is shown that the additional factor (j/j0) in the velocity is necessity to explain the experimental finding of the dependence of time scale t0 on the ac field amplitude.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.